Health
Less Is More: Training-Free Acceleration Framework of 3D Diffusion Models for Low-Count PET Denoising via Global-Local Trajectory Reduction
Key Points
arXiv:2606.08751v1 Announce Type: new Abstract: Accurate quantification and uptake measurement in PET are critical for assessing disease progression and supporting clinical decision-making. While high-count PET provides reliable image quality, the associated radiation dose and prolonged acquisition remain significant clinical concerns, motivating the adoption of low-count protocols. Diffusion-model-based methods have demonstrated strong potential for restoring low-count PET to near...
arXiv:2606.08751v1 Announce Type: new
Abstract: Accurate quantification and uptake measurement in PET are critical for assessing disease progression and supporting clinical decision-making. While high-count PET provides reliable image quality, the associated radiation dose and prolonged acquisition remain significant clinical concerns, motivating the adoption of low-count protocols. Diffusion-model-based methods have demonstrated strong potential for restoring low-count PET to near high-count quality, but their iterative sampling procedure becomes prohibitively expensive when applied to high-resolution 3D PET volumes, introducing substantial inference latency that limits practical clinical deployment. To address these challenges, we propose a training-free Global-Local Skipping Strategy that accelerates diffusion model-based 3D PET denoising while simultaneously improving reconstruction quality. The proposed method is plug-and-play and directly applicable to pre-trained diffusion models without retraining or architectural modification. Specifically, we introduce: (i) a global denoising step skipping strategy that initializes the reverse diffusion process from an intermediate denoising step using a noise-consistent transformation of the low-count input, substantially reducing the number of required denoising steps; and (ii) a local feature reuse shortcut that reuses slowly-varying high-level U-Net features across neighboring denoising steps, further reducing per-step computation while preserving image fidelity. We evaluate the proposed approach on multiple PET tracers from in-house and public datasets, including 18F-FDG PET, 68Ga-DOTATATE PET, and 18F-PSMA PET, demonstrating consistent acceleration of over an order of magnitude alongside improved or comparable reconstruction performance relative to the full-step baseline. Blinded reader studies further confirm enhanced clinical confidence and perceived diagnostic quality.