Science
Radiation damage studies of silicon photomultipliers for the CMS MIP Timing Detector
Key Points
arXiv:2606.10121v1 Announce Type: new Abstract: Recently developed 15 um, 20 um, 25 um and 30 um cell size Hamamatsu Silicon Photomultipliers (SiPMs) were irradiated with reactor neutrons at JSI (Ljubljana) up to 2*10^14 n/cm^2 (1 MeV equivalent). The parameters of new and irradiated SiPMs were studied using pulsed light illumination. The effects of the neutron radiation on breakdown voltage, signal amplitude, dark current and noise for these devices are shown and discussed.
arXiv:2606.10121v1 Announce Type: new
Abstract: Recently developed 15 um, 20 um, 25 um and 30 um cell size Hamamatsu Silicon Photomultipliers (SiPMs) were irradiated with reactor neutrons at JSI (Ljubljana) up to 2*10^14 n/cm^2 (1 MeV equivalent). The parameters of new and irradiated SiPMs were studied using pulsed light illumination. The effects of the neutron radiation on breakdown voltage, signal amplitude, dark current and noise for these devices are shown and discussed.