Home Health Gait2Hip-60: A Unified Deep Learning Benchmark for...
Health

Gait2Hip-60: A Unified Deep Learning Benchmark for Predicting Hip Muscle Forces and Joint Moments from Multi-Cadence Gait Kinematics

Key Points

Announce Type: new Abstract: Estimating hip muscle forces and joint moments during gait typically relies on musculoskeletal simulation, which is informative but time-consuming and difficult to apply in clinical settings. This study developed a deep learning framework to predict these hip dynamics parameters directly from lower-limb gait kinematics and compared three representative sequence models under a unified protocol. Gait data were collected from 60 healthy adults under three...

arXiv:2605.30374v1 Announce Type: new Abstract: Estimating hip muscle forces and joint moments during gait typically relies on musculoskeletal simulation, which is informative but time-consuming and difficult to apply in clinical settings. This study developed a deep learning framework to predict these hip dynamics parameters directly from lower-limb gait kinematics and compared three representative sequence models under a unified protocol. Gait data were collected from 60 healthy adults under three metronome-guided cadence conditions. Ten bilateral lower-limb joint angles were used as inputs, and OpenSim-derived hip muscle forces and hip joint moments were used as reference outputs. Three deep learning models of LSTM, Transformer, and Mamba were trained and evaluated using the same subject-level split, preprocessing pipeline, and metrics. The best model was then directly tested on an external cohort of 9 patients with osteonecrosis of the femoral head (ONFH) without retraining. In the healthy-subject benchmark, Transformer achieved the best subject-level mean performance for both hip muscle force prediction (RMSE = 1.33 N/kg, MAE = 0.57 N/kg, R2 = 0.819) and hip joint moment prediction (RMSE = 0.11 Nm/kg, MAE = 0.07 Nm/kg, R2 = 0.862), with similar advantages across walking cadences. In zero-shot external validation, Transformer retained moderate predictive ability in ONFH for hip muscle force prediction (RMSE = 1.51 N/kg, MAE = 0.70 N/kg, R2 = 0.537) and hip joint moment prediction (RMSE = 0.17 Nm/kg, MAE = 0.12 Nm/kg, R2 = 0.569). These findings support the feasibility of estimating hip dynamics from gait kinematics, identify Transformer as a strong baseline, and highlight the need for broader pathological validation and improved generalization before clinical application.
Gait2Hip-60 (PERSON) Multi-Cadence Gait Kinematics (ORG) OpenSim (ORG) LSTM (ORG) Transformer (ORG) Mamba (ORG) RMSE (ORG) MAE (ORG) ONFH (LOCATION)
Originally published by arXiv CS Read original →