Home › Health › Feature Scaling Beats Architecture Choice in Offline...
Health

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

Key Points

arXiv:2610.33030v1 Announce Type: new Abstract: Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary...

arXiv:2610.33030v1 Announce Type: new Abstract: Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.
SVM (ORG) MFCC (PERSON) RBF (ORG) SMOTE (ORG) SpecAugment (ORG) CPU (ORG) MB PyTorch (ORG) Cramer (ORG)
Originally published by arXiv CS Read original →